Capillary electrophoresis method, is one of the fastest development analysis methods in recent years. High voltage electric field as the driving force,based on a capillary as separation channel,between the various components of the sample based on mobility and distribution of the difference in behavior to achieve separation of the liquid phase separation method.
The power supply has time drift, drift is small, high stability, low output ripple, anti-jamming performance, high conversion efficiency, the output voltage is continuously adjustable, output voltage and current digital monitoring shows high accuracy.It also has over voltage, short circuit protection and other features such as soft start.
Capillary electrophoresis method, is one of the fastest development analysis methods in recent years. High voltage electric field as the driving force,based on a capillary as separation channel,between the various components of the sample based on mobility and distribution of the difference in behavior to achieve separation of the liquid phase separation method.
The power supply has time drift, drift is small, high stability, low output ripple, anti-jamming performance, high conversion efficiency, the output voltage is continuously adjustable, output voltage and current digital monitoring shows high accuracy.It also has over voltage, short circuit protection and other features such as soft start.
Specification:
Input Voltage:AC220V±10% 50/60Hz
Output Parameters:
Output Voltage |
Output Current |
Maximum Output Power |
Output Channel |
0 to 5000V |
<2mA |
10W |
Single,multiple channel optional |
0 to 10KV |
<2mA |
20W |
Single,multiple channel optional |
0 to 20KV |
<2mA |
40W |
Single,multiple channel optional |
0 to 30KV |
<2mA |
60W |
Single,multiple channel optional |
Positive negative polarity output optional;
0V to the maximum voltage is continuously adjustable
No load to the maximum output current
Other parameters required or technical problems, please contact us
Voltage Regulation:< 0.1 % (AC220V±10%)
Load Regulation:< 0.1% (No load to full load)
Control Method:local control,remote control optional
The control: adjustment knob: the output voltage can be adjusted continuously
Start / stop control switch: startup, shutdown, high voltage power supply
Power switch: the whole supply switch
Remote control: Voltage Remote Control
Terminal remote control: computer programming control, PLC control, etc.
Time drift:< 0.1%/h (start in 30 minutes)
temperature drift:< 0.1%/℃
environment temperature:
working temperature:-10℃~+50℃; storage temperature:-10℃~+80℃。
Protection:over-voltage、over-current、short-circuit protection
Soft-start function:machine starts with a soft-start function
Dimensions: